Wow, its been over 2 years since I last posted. You can see I'm not a great blogger!
In April 2013 I had my third DiaPort implanted, my first of the new generation. This one is 'new, improved!!!' in the following ways:
✫ it has a single internal catheter (rather than a catheter surrounded by a sheath)
✫ the catheter is much softer (it will move around more easily and avoid provoking the omentum to overgrow)
✫ and a felt cuff around the port where it emerges through the skin (so the skin will form a tighter seal and better infection protection)
My wounds are healing well, and the new Diaport has behaved excellently from the moment it was implanted (yes, they plugged me in while I was still on the operating table!).
I know there isn't a lot of info about the Diaport on the www, so when people search they may find this blog and little else. I know that Roche are working to make information available to potential patients, but in the meantime more up-to-date information (hopefully) and chat (for sure) can be found on Facebook at DiaPort users
In signing off, I would like to say that with all my experience of the Diaport, even the first generation (my first two ports) and the associated laparoscopies to clear away the overgrown omentum, I would still recommend this excellent piece of kit to anyone who is struggling with subcutaneous pump therapy.
Cheers!
DiaPort User
I use a DiaPort, which is a surgically implanted device for continuous intraperitoneal infusion of insulin. I hope this blog will become a resource and e-meeting point for all English-speaking DiaPort users across the world.
Wednesday, May 8, 2013
Thursday, November 11, 2010
Update November 2010
Having posted my story so far, I'd better keep it updated!
May 2009 - 2nd DiaPort implanted. This was a bit of a shot in the dark as none of the UK team had experience of the need to renew the DiaPort. It was not behaving well - absorption seemed to be unreliable and I was struggling with my blood glucose results, so the diabetologist reluctantly agreed it was worth trying a new implant.
July 2010 - DiaPort blocked. Laparoscopy under general anaesthetic showed my omentum had overgrown the cannula. This solved the problem for all of 3 weeks, before it became blocked again. At this point I started to worry - I can't have an anaesthetic once a month to keep this going, and my subcut sites were still not good. Maybe it was time for a new DiaPort even though I'd only had this one for just over a year. However, the new improved DiaPort was not yet available and the old one (the type I currently have) is no longer available. If this one couldn't be salvaged I'd have to struggle with subcut infusions until 2012.
I started to get into a routine with subcut infusion sites - rediscovering which areas were just no good, and which ones weren't too bad. I used a different type of cannula above/below the waistline and changed every 2 days even if it should have been a 3-day cannula.
November 2010 - The time came for the regular revision. A guide wire confirmed that it was indeed blocked and whatever was causing the blockage couldn't be persuaded to move aside! Fortunately the surgeon managed to slot me in for a laparoscopy (my second this year) and the pesky omentum overgrowth was cut away again, along with some adhesions.
Its such a relief to be using the DiaPort again, and my blood glucose results are great - which just proves it was worth it. I hope it stays clear much longer this time!
May 2009 - 2nd DiaPort implanted. This was a bit of a shot in the dark as none of the UK team had experience of the need to renew the DiaPort. It was not behaving well - absorption seemed to be unreliable and I was struggling with my blood glucose results, so the diabetologist reluctantly agreed it was worth trying a new implant.
July 2010 - DiaPort blocked. Laparoscopy under general anaesthetic showed my omentum had overgrown the cannula. This solved the problem for all of 3 weeks, before it became blocked again. At this point I started to worry - I can't have an anaesthetic once a month to keep this going, and my subcut sites were still not good. Maybe it was time for a new DiaPort even though I'd only had this one for just over a year. However, the new improved DiaPort was not yet available and the old one (the type I currently have) is no longer available. If this one couldn't be salvaged I'd have to struggle with subcut infusions until 2012.
I started to get into a routine with subcut infusion sites - rediscovering which areas were just no good, and which ones weren't too bad. I used a different type of cannula above/below the waistline and changed every 2 days even if it should have been a 3-day cannula.
November 2010 - The time came for the regular revision. A guide wire confirmed that it was indeed blocked and whatever was causing the blockage couldn't be persuaded to move aside! Fortunately the surgeon managed to slot me in for a laparoscopy (my second this year) and the pesky omentum overgrowth was cut away again, along with some adhesions.
Its such a relief to be using the DiaPort again, and my blood glucose results are great - which just proves it was worth it. I hope it stays clear much longer this time!
Update
Hi
No responders so far!
Since starting the blog, I have heard that although approx 200 DiaPorts were implanted worldwide, there are only around 20 of us still using a DiaPort.
Here is my story, copied from http://www.insulin-pumpers.org.uk/diaport/
My DSN suggested a pump in August 2002 because of my unpredictable blood glucose levels due to lipohypertrophy. I started pumping in September 2002 and gained the best control I’d had in years. After about a year, I saw signs that the lipo problem was going to become an issue again with my infusion sites. I saw my DSN and tried a few new areas. However, despite rotating infusion sites, some sites felt slightly lumpy beneath the skin, and became less and less reliable. I thus had to avoid these sites. Even after a couple of months of avoiding them, if I went back to them nothing had changed. I could still keep good control, but had fewer and fewer comfortable, reliable infusion sites as time went on.
I asked IP-UK list members for suggestions, and amongst them was the DiaPort. So I telephoned the DSN at the Royal Bournemouth Hospital, where a limited trial of the DiaPort had all but closed down due to lack of uptake and 1 in 3 failure of the port. Joan Everett, the DSN, asked me to get a referral from my usual diabetes care team (in Essex) to Bournemouth, just for the port (that is, not for my ongoing diabetes care). I saw my diabetologist in August 2004, and a letter was sent in September. I saw Joan and Dr David Kerr in November 2004. Dr Kerr agreed that the lipo was the problem, and suggested that the DiaPort could be a solution. He ran through the drawbacks, and Joan gave me the telephone numbers of the other 2 patients who still had a DiaPort, so I could get the patient’s point of view.
Drawbacks
Risk of site infection
Risk of blockage
Risk of peritonitis
Benefits
Avoids subcutaneous tissue damage
No skin irritation from nickel or infusion set adhesives
No needles even when changing the infusion set
Uptake by hepatic circulation is more like real pancreatic release than via peripheral circulation
Rapid and reliable effect of insulin (starts after 3 minutes)
I spoke to another DiaPort patient and decided to go ahead.
The port was inserted under general anaesthetic on 20 December 2004. I had to stay in hospital for 2 nights; the night before and the night after surgery. There were 2 wounds – one where the port pokes through the skin, and another, about 2 inches long, where the surgeon’s fingers did their thing! Infusion was transferred to the port immediately.
Recovery was awful for the first couple of days. I was much more comfortable than I expected to be, and only took paracetamol to kill the pain for a few days. But my blood glucose levels were very difficult to bring down. Although the standard procedure is to reduce the insulin dose by 10%, I needed large correction boluses for the first night, and even a subcut injection when ketones showed up. Eventually Joan and I got it under control and kept it there with a temporary basal rate of around 180%.
The only visible part is a metal bit like the tip of a tube, about half a centimetre high and half a centimetre wide, that pokes through the skin. This is fixed in place with a plastic wheel-like thing, about 2cm diameter, which I have to wear for the first 3 months. There is also a plastic cannula of about 10cm underneath the skin that reaches into my peritoneal cavity. I have to go back to Bournemouth to have the inner catheter changed every 3 months. This will be done within a few minutes by the surgeon, in the day theatre, without any need for anaesthetic.
Daily care was a bit daunting at first, but then so was daily care of the infusion sites when I started pumping. After a month, I didn’t need to wear a wound dressing. Now I just have to clean the area with an alcohol swab every day, and make sure I only handle it with clean hands. But isn’t that the same with subcut infusions?
Using the port has certainly solved the infusion site problems! It’s always in the same spot, and always reliable. Even a big pizza bolus doesn’t sting, and I can change the infusion set last thing at night, if I need to. Such freedom!
I have had one superficial site infection. The area looked red and oozy, and began to itch. My GP gave me a week’s worth of antibiotics and things settled down again.
The port is very comfortable, I don’t even know it’s there, unlike some infusion sets, which I couldn’t wait to take out after a couple of days. It’s perhaps slightly less discrete than the low profile infusion sets, but it hasn’t been a problem to me.
My only concern now is that I seem to be building up insulin resistance. Prior to the DiaPort insertion, I needed 25 units of basal insulin per day. This has increased to at least 49 units a day, and it seems that every time I need to have a “temporary” basal increase, it doesn’t quite settle back to 100%. So I’m not sure what will happen in the long term.
Apart from that, I’m very happy with the DiaPort, and would recommend it to anyone with ongoing infusion site problems. Those with allergies or needle phobia would also benefit.
Update May 2005: I'm now using 97 basal units per day. My blood glucose levels are often unpredictable, and my daily insulin profile has changed so that my peak insulin delivery is between midday and midnight. This is unacceptable so I have arranged an appointment to discuss this with Dr Kerr - until now, the team seemed uninterested and reluctant to admit this is a problem. However, having agreed to an appointment, they sent one that's only 2 weeks away, which must be pretty good for a busy diabetes outpatient clinic. The protocol for under-delivery shows that an x-ray with radiopaque dye is the next step, to show up any fibrous tissue gathering at the end of the inner catheter. If that's what's causing the problem, then I may need a laparoscopy to clear this tissue.
Update late May 2005: Under general anaesthetic, laparoscopy showed the catheter was completely embedded in the omentum (part of the peritoneum) and surrounded by crystallised insulin. They removed the overgrown omentum and chipped away at the insulin, then inserted a new inner and outer catheter. Time will tell if it will remain clear and function well.
Update July 2005: My basal rates have been increasing steadily again, and another x-ray with dye showed some new crystallisation. At the end of the month I will swap insulin from Humalog to Insuman Infusat, and start flushing with saline every 2 weeks, to try to prevent crystallisation.
No responders so far!
Since starting the blog, I have heard that although approx 200 DiaPorts were implanted worldwide, there are only around 20 of us still using a DiaPort.
Here is my story, copied from http://www.insulin-pumpers.org.uk/diaport/
My DSN suggested a pump in August 2002 because of my unpredictable blood glucose levels due to lipohypertrophy. I started pumping in September 2002 and gained the best control I’d had in years. After about a year, I saw signs that the lipo problem was going to become an issue again with my infusion sites. I saw my DSN and tried a few new areas. However, despite rotating infusion sites, some sites felt slightly lumpy beneath the skin, and became less and less reliable. I thus had to avoid these sites. Even after a couple of months of avoiding them, if I went back to them nothing had changed. I could still keep good control, but had fewer and fewer comfortable, reliable infusion sites as time went on.
I asked IP-UK list members for suggestions, and amongst them was the DiaPort. So I telephoned the DSN at the Royal Bournemouth Hospital, where a limited trial of the DiaPort had all but closed down due to lack of uptake and 1 in 3 failure of the port. Joan Everett, the DSN, asked me to get a referral from my usual diabetes care team (in Essex) to Bournemouth, just for the port (that is, not for my ongoing diabetes care). I saw my diabetologist in August 2004, and a letter was sent in September. I saw Joan and Dr David Kerr in November 2004. Dr Kerr agreed that the lipo was the problem, and suggested that the DiaPort could be a solution. He ran through the drawbacks, and Joan gave me the telephone numbers of the other 2 patients who still had a DiaPort, so I could get the patient’s point of view.
Drawbacks
Risk of site infection
Risk of blockage
Risk of peritonitis
Benefits
Avoids subcutaneous tissue damage
No skin irritation from nickel or infusion set adhesives
No needles even when changing the infusion set
Uptake by hepatic circulation is more like real pancreatic release than via peripheral circulation
Rapid and reliable effect of insulin (starts after 3 minutes)
I spoke to another DiaPort patient and decided to go ahead.
The port was inserted under general anaesthetic on 20 December 2004. I had to stay in hospital for 2 nights; the night before and the night after surgery. There were 2 wounds – one where the port pokes through the skin, and another, about 2 inches long, where the surgeon’s fingers did their thing! Infusion was transferred to the port immediately.
Recovery was awful for the first couple of days. I was much more comfortable than I expected to be, and only took paracetamol to kill the pain for a few days. But my blood glucose levels were very difficult to bring down. Although the standard procedure is to reduce the insulin dose by 10%, I needed large correction boluses for the first night, and even a subcut injection when ketones showed up. Eventually Joan and I got it under control and kept it there with a temporary basal rate of around 180%.
The only visible part is a metal bit like the tip of a tube, about half a centimetre high and half a centimetre wide, that pokes through the skin. This is fixed in place with a plastic wheel-like thing, about 2cm diameter, which I have to wear for the first 3 months. There is also a plastic cannula of about 10cm underneath the skin that reaches into my peritoneal cavity. I have to go back to Bournemouth to have the inner catheter changed every 3 months. This will be done within a few minutes by the surgeon, in the day theatre, without any need for anaesthetic.
Daily care was a bit daunting at first, but then so was daily care of the infusion sites when I started pumping. After a month, I didn’t need to wear a wound dressing. Now I just have to clean the area with an alcohol swab every day, and make sure I only handle it with clean hands. But isn’t that the same with subcut infusions?
Using the port has certainly solved the infusion site problems! It’s always in the same spot, and always reliable. Even a big pizza bolus doesn’t sting, and I can change the infusion set last thing at night, if I need to. Such freedom!
I have had one superficial site infection. The area looked red and oozy, and began to itch. My GP gave me a week’s worth of antibiotics and things settled down again.
The port is very comfortable, I don’t even know it’s there, unlike some infusion sets, which I couldn’t wait to take out after a couple of days. It’s perhaps slightly less discrete than the low profile infusion sets, but it hasn’t been a problem to me.
My only concern now is that I seem to be building up insulin resistance. Prior to the DiaPort insertion, I needed 25 units of basal insulin per day. This has increased to at least 49 units a day, and it seems that every time I need to have a “temporary” basal increase, it doesn’t quite settle back to 100%. So I’m not sure what will happen in the long term.
Apart from that, I’m very happy with the DiaPort, and would recommend it to anyone with ongoing infusion site problems. Those with allergies or needle phobia would also benefit.
Update May 2005: I'm now using 97 basal units per day. My blood glucose levels are often unpredictable, and my daily insulin profile has changed so that my peak insulin delivery is between midday and midnight. This is unacceptable so I have arranged an appointment to discuss this with Dr Kerr - until now, the team seemed uninterested and reluctant to admit this is a problem. However, having agreed to an appointment, they sent one that's only 2 weeks away, which must be pretty good for a busy diabetes outpatient clinic. The protocol for under-delivery shows that an x-ray with radiopaque dye is the next step, to show up any fibrous tissue gathering at the end of the inner catheter. If that's what's causing the problem, then I may need a laparoscopy to clear this tissue.
Update late May 2005: Under general anaesthetic, laparoscopy showed the catheter was completely embedded in the omentum (part of the peritoneum) and surrounded by crystallised insulin. They removed the overgrown omentum and chipped away at the insulin, then inserted a new inner and outer catheter. Time will tell if it will remain clear and function well.
Update July 2005: My basal rates have been increasing steadily again, and another x-ray with dye showed some new crystallisation. At the end of the month I will swap insulin from Humalog to Insuman Infusat, and start flushing with saline every 2 weeks, to try to prevent crystallisation.
Thursday, July 22, 2010
Link to old DiaPort brochure
Here is a link to the pre-2005 DiaPort brochure
Wednesday, July 21, 2010
New blog from a DiaPort user
Hi
I've used a DiaPort since 2004. When I recently tweeted about it, I looked for a link to explain DiaPort and found precious little info on the web in English.
I understand there are currently around 200 users across the globe, so I thought I'd set up a place to e-meet and share info.
Please leave a comment!
Cheers
Lesley